§ 17.22.070. Site development standards.


Latest version.
  • In the RR zone, the following site development standards apply:

    A.

    Minimum parcel size for new parcels:

    1.

    With individual well and on-site sewage disposal system: five acres,

    2.

    With public water and on-site sewage disposal system: one acre,

    3.

    With public water and public sewage disposal: one acre, unless a one-half-acre parcel size is permitted under the provisions of an applicable community or special plan;

    B.

    Maximum density:

    1.

    With individual well and on-site sewage disposal system: one dwelling per five acres,

    2.

    With public water and on-site sewage disposal system: one dwelling per one acre,

    3.

    With public water and public sewage disposal: one dwelling per one acre, unless a one-half-acre parcel size is permitted under the provisions of a community or special plan;

    C.

    Maximum lot coverage: twenty-five percent;

    D.

    Maximum building height: thirty-five feet;

    E.

    Lot width:

    1.

    Average: one hundred feet,

    2.

    At the road: twenty feet, or fifteen feet when access is shared with the adjacent parcel;

    F.

    Lot depth:

    1.

    Average: one hundred feet,

    2.

    Minimum: one hundred feet;

    G.

    Minimum building setbacks:

    1.

    For purposes of this chapter the following shall apply:

    a.

    Front, twenty feet from the property line, or fifty feet from the centerline of the road right-of-way or easement, whichever distance is greater,

    b.

    Corner, or lots with multiple lot lines fronting roads, same distance as front for all property lines fronting road rights-of-way or easements,

    c.

    Side, ten feet,

    d.

    Rear, twenty feet,

    e.

    Between buildings, ten feet, or the requirements of the responsible fire agency, whichever is greater,

    f.

    Vision clearance, thirty-five feet,

    2.

    In addition to the setbacks specified in subsection (G)(1) of this section, minimum building setbacks shall meet the requirements of Section 8.10.120 of this code in order to achieve defensible space, which requires a thirty-foot setback from all property lines and/or center of the road for parcels one acre or larger, and same practical effect shall be provided for parcels less than one acre. Procedures for exceptions to these standards shall comply with Sections 8.10.150 and 8.10.190 of this code.

(Ord. 2345 § 3 Exh. A(part), 1993; Ord. 1782 § 1(part), 1986).